Leuze electronic CML 720i Ex Operating Instructions Manual page 88

Measuring light curtain
Table of Contents

Advertisement

Parameter
Number of teach cycles
Type of storage for teach values
Sensitivity adjustment for teach event
Teach status
Blanking settings (group 7)
Up to four beam areas can be deactivated. Deactivated beams can be assigned the logical
values 0, 1 or the value of the adjacent beam. With auto blanking activated, up to four beam
areas are automatically suppressed during teaching.
Auto blanking should only be activated during commissioning of the CML 700i to suppress inter-
fering objects. In process mode, auto blanking should be deactivated.
For details on this topic see chapter 11.4.
NOTICE
Perform teach after changing the blanking configuration!
 Perform a teach after changing the blanking configuration.
A teach can be performed via the receiver control panel or via the teach command.
Leuze electronic
Index
Sub-
Data
Access
(hex.)
index
type
(hex.)
2103
1
t08U
RO
2103
2
t08U
RW
2103
3
t08U
RW
2400
1
t08S
RO
CML 720i Ex
Starting up the device - CANopen interface
Min.
Max. value
Default Explanation
value
10
Depending on the environ-
mental conditions or applica-
tion, the light curtain may
have completed multiple
cycles after the triggering of a
teach.
0
1
0
0: Non-volatile storage of
teach values
1: Teach values stored only
while voltage is ON
0
Sensitivity of the measure-
ment system:
0: High function reserve (for
stable operation)
1: Medium function reserve
2: Low function reserve
0
MAX_T08U
Information about the last
teach:
00: Teach ok
01: Teach busy
80: Teach error (bit 8 = error
bit)
88