Level 0
Level 1
Main Settings
Commands
Operational setting
 Select Main Settings > Operational Settings > Function Reserve
8.5

Extended configurations on the receiver control panel menu

It is not mandatory that extended configurations be performed on the receiver control panel menu
in order to start up a light curtain.
8.5.1
Define digital inputs/outputs
The digital IOs, IO pin x configurations (IO function, inversion, area logic, start beam, end beam, etc.) are
used to configure the parameters for the switching outputs.
The individual configuration steps for the extended configuration combinations are not described
separately.
When configuring start and end beam, you can configure values of up to 1774. Values above
1774 (to 1999) are not accepted and must be entered again.
The structure of these configurations in the receiver control panel menu is as follows (multiple configura-
tions displayed simultaneously):
Examples
Configuration of pin 2 as PNP switching output
The following example shows a configuration of pin 2 as PNP switching output with additional configura-
tions, such as area logic "OR" with a beam area of 1 ... 32 and beam 1 as start beam according to the
following table.
Start beam
End beam
Switch-on condition
Switch-off condition
Level 0
Level 1
Digital IOs
IO Logic
IO Pin 2
Leuze electronic
Level 2
Description
Teach
Filter depth
Beam mode
Function reserve
High
Level 2
Description
Positive PNP
IO Function
Trigger input
Inversion
Normal
Teach height
Execute
Area Logic
AND
CML 720i Ex
Starting up the device - Basic configuration
Reset
Medium
OR
1
32
1 beam interrupted
0 beams interrupted
Negative NPN
Teach input
Area Output
Inverted
Exit
OR
Factory settings
Low
Warning output
Trigger output
61