Figure 4.16: Teaching the height area with the "Teach in height area"
• To define the entire beam area as a height area, teaching of the height area is performed without an
object (all beams free).
Figure 4.17: Teaching of the total beam area as height area without object
• The switching behavior or the conditions for switching the height area on or off via the "Teach height
area" function is permanently defined as OR.
• Every IO pin can be assigned to a height area via the receiver control panel.
Example: Digital IOs > IO Pin 2 > Teach height > Execute
On the receiver control panel, the "Teach height area" function is activated via the Teach height
menu item. Example: Digital IOs > IO Pin 2 > Teach height > Execute
If the "Teach height area" function is activated via the receiver control panel, the IO pins are auto-
matically assigned to the height areas.
Example configurations for the assignment of previously defined height areas to switching outputs Q1 to
Q4:
• see chapter 11.2 "Example configuration - Mapping of beams 1 ... 32 to output pin 2"