Leuze electronic CML 720i Ex Operating Instructions Manual page 120

Measuring light curtain
Table of Contents

Advertisement

Table 13.4:
Error code
RxS 0x1000
RxS 0x1100
RxS 0x1001
RxS 0x11xy
RxS 0x111x
RxS 0x112x
RxS 0x113x
Table 13.5:
Error code
RxS 0x2000
RxS 0x2001
RxS 0x2100
RxS 0x2200
RxS 0x23xy
Leuze electronic
Warnings
Description
Device in teach mode, no new
process data available
Teaching error
Trigger frequency too high
The device could not end
teach, no new process data
available
Blanking error
Error due to weak signal
Individual beams do not reach
the minimum reception level
Internal error
Device has reached the
power limit
Errors (can be corrected)
Description
No communication possible between transmitter and
receiver.
Receiver/transmitter inconsistency.
The receiver is not compatible with the transmitter.
The supply voltage is not sufficient.
EEPROM data corrupt.
Configuration error.
xy gives information on the type of configuration error.
Possible cause (s)
• Distance between transmitter and receiver too large
or too small
• Poor alignment
• Soiling
• Extraneous light, especially mutual interference
• Beams are interrupted, but blanking is deactivated
• The maximum number of blanking areas is not suffi-
cient
• The number of beams to be blanked is greater than
or equal to the number of all logical beams
CML 720i Ex
Troubleshooting
Measures
Check cable.
Replace transmitter.
Check voltage supply.
Reset device to factory set-
tings.
Contact service (see
chapter 15).
Reset device to factory set-
tings.
Check parameters and
parameter relation.
120