Parameter
First interrupted beam
(FIB)
First not interrupted
beam (FNIB)
Last interrupted beam
(LIB)
Last not interrupted
beam (LNIB)
Total of interrupted
beams (TIB)
Total of not interrupted
beams (TNIB)
Area Out - LoWord
Area Out - HiWord
Result of the area evalu-
ation mapped to pins
Reserved
Pin 7
Pin 6
Pin 5
Pin 2
HW analog (HWA)
PD beam-stream
PD beam-stream
PD beam-stream
PD beam-stream
Leuze electronic
Index
Sub-
Data type
index
150
0
unsigned 16
151
0
unsigned 16
152
0
unsigned 16
153
0
unsigned 16
154
0
unsigned 16
155
0
unsigned 16
158
0
unsigned 16
159
0
unsigned 16
160
0
record 16 bit,
isolated
access to
sub-index not
possible
160
1
unsigned 16
(bit
offset
= 4)
160
2
boolean
(bit
offset
= 3)
160
3
boolean
(bit
offset
= 2)
160
4
boolean
(bit
offset
= 1)
160
5
boolean
(bit
offset
= 1)
161
0
unsigned 16
171
0
array
172
0
array
173
0
array
174
0
array
Starting up the device - IO-Link interface
Access Value range
Default Explanation
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
CML 720i Ex
Logical beam number of the first darkened individ-
ual beam. The logical beam numbers change to
the "diagonal" or "crossed-beam" mode. Note any
changed configuration of the counting direction!
Logical beam number of the first undarkened indi-
vidual beam. The logical beam numbers change to
the "diagonal" or "crossed-beam" mode. Note any
changed configuration of the counting direction!
Logical beam number of the last darkened individ-
ual beam. The logical beam numbers change in
diagonal- or crossed-beam mode. Note any
changed configuration of the counting direction!
Logical beam number of the last undarkened indi-
vidual beam. The logical beam numbers change to
the "diagonal" or "crossed-beam" mode. Note any
changed configuration of the counting direction!
Sum of all darkened individual beams. The sum
changes to the " or """crossed-beam" mode.
Sum of all undarkened individual beams. The sum
changes to the "diagonal" or "crossed-beam"
mode.
Status of areas 01 ... 16 as 2 bytes of process data
Status of areas 17 ... 32 as 2 bytes of process data
Logical status of the area evaluations mapped to
the pin
8 bytes
16 bytes
32 bytes
64 bytes
80