8.3.2

Rated data

E82ZWBRB brake switch
ƒ
Range
Input voltage
Input current
Output voltage
Maximum brake current
Control input
Control voltage
Control current
Protective function
Maximally connectable cable
cross−section
E82ZWBRE brake switch
ƒ
Range
Input voltage
Input current
Output voltage
Maximum brake current
Control input
Control voltage
Control current
Protective function
Min. permissible switch−off
time
Maximally connectable cable
cross−section
EDS84ASC552 EN 6.0
efesotomasyon.com - Lenze
Operation with spring−applied brake
Values
1/N/PE AC 230 V (AC 180 ... 264 V), 45 ... 65 Hz
2/PE AC 230 V (AC 180 ... 264 V), 45 ... 65 Hz
AC 0.1 ... 0.54 A
DC 205 V
at AC 230 V mains voltage
DC 0.41 A
Installation in 8200 motec
DC 0.54 A
Installation in control cabinet
DC 24 V, PLC−level
HIGH
DC +15 ... 30 V
LOW
DC 0 ... +3 V
5 ... 10 mA
Protected against polarity reversal until DC 60 V
2
1.5 mm
AWG 16
Values
3/PE AC 400 V (AC 320 ... 550 V), 45 ... 65 Hz
AC 0.1 ... 0.61A
DC 180 V
at AC 400 V mains voltage
DC 225 V
at AC 500 V mains voltage
DC 0.47 A
Installation in 8200 motec
DC 0.61 A
Installation in control cabinet
DC 24 V, PLC−level
HIGH
DC +15 ... 30V
LOW
DC 0 ... +3 V
5 ... 10 mA
Protected against polarity reversal until DC 60 V
t
>20ms
off
2
1.5 mm
AWG 16
l
Braking operation
Rated data
8
159