Analog Inputs And Outputs - Lenze 8400 StateLine C Hardware Manual

L-force drives frequency inverter
Hide thumbs Also See for 8400 StateLine C:
Table of Contents

Advertisement

6.6.2

Analog inputs and outputs

X3
Fig. 6−25
Labelling
Controller
A1U
A1I
GA
O1U
Terminal data
flexible
with wire end ferrule
EDS84ASC552 EN 6.0
efesotomasyon.com - Lenze
Connection of the analog inputs and outputs
Description
Reference voltage 10 V
Analog input 1
GND analog signals
Analog output 1
Conductor cross−section
2
[mm
]
0.2 ... 1.5
l
Electrical installation
StateLine C control terminals
Analog inputs and outputs
GND
X3
O1U GA A1I A1U AR
"
0 ...10 V
2 mA
8400SLC042
±10V (^ 55)
0 ...+20 mA/+4 ...+20 mA (^ 55)
0 ... +10 V (^ 55)
Tightening torque
[AWG]
[Nm]
24 ... 16
6
+10 V /
10 mA
1k ... 10k
8400SLC043
!
[lb−in]
2.5 x 0.4
129

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

8400 highline c

Table of Contents