Operation At Rated Mains Voltage 500 V - Lenze 8400 StateLine C Hardware Manual

L-force drives frequency inverter
Hide thumbs Also See for 8400 StateLine C:
Table of Contents

Advertisement

8
Braking operation
Braking operation with external brake resistor

Operation at rated mains voltage 500 V

8.2.3
Operation at rated mains voltage 500 V
Switching threshold V
Type
E84AVxxx3714
E84AVxxx5514
E84AVxxx7514
E84AVxxx1124
E84AVxxx1524
E84AVxxx2224
E84AVxxx3024
E84AVxxx4024
E84AVxxx5524
E84AVxxx7524
E84AVxxx1134
E84AVxxx1534
E84AVxxx1834
E84AVxxx2234
152
efesotomasyon.com - Lenze
: 790 V, adjustable
BRmax
R
I
Bmin
BRmax
[W]
[A]
390
2.0
390
2.0
390
2.0
180
4.4
180
4.4
150
5.3
47
16.8
47
16.8
47
16.8
27
29.3
27
29.3
18
43.9
15
52.7
15
52.7
R
Minimum brake resistance, nominal value ±10 %
Bmin
I
Peak current
BRmax
P
Peak braking power
BRmax
I
Continuous current RMS − important for the dimensioning of the cables
BRd
P
Continuous braking power
Bd
t
Cycle time, periodic load change with running time and recovery time
Z
t
Running time
on
t
− t
Recovery time
Z
on
t
Maximum running time without initial load and compliance with the recovery
fp
time
l
P
I
P
BRmax
BRd
Bd
[kW]
[A]
[kW]
1.6
2.0
1.6
1.6
2.0
1.6
1.6
2.0
1.6
3.5
4.4
3.5
3.5
4.4
3.5
4.2
5.3
4.2
13.3
13.0
10.3
13.3
13.0
10.3
13.3
13.0
10.3
23.1
29.3
23.1
23.1
29.3
23.1
34.7
43.9
34.7
41.6
52.7
41.6
41.6
52.7
41.6
t
t
t
Z
on
fp
[s]
[s]
[s]
¥
¥
¥
¥
¥
¥
¥
¥
¥
¥
¥
¥
¥
¥
EDS84ASC552 EN 6.0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

8400 highline c

Table of Contents