Type Code - Lenze 8400 StateLine C Hardware Manual

L-force drives frequency inverter
Hide thumbs Also See for 8400 StateLine C:
Table of Contents

Advertisement

3
Product description

Type code

3.5
Type code
Product range
8400 Inverter Drives
Version
A = 1st generation
Inverter type
V = vector−controlled inverter
Version
SC = StateLine C
HC = HighLine C
Mounting type
E = installation
D = Push−trough technique
C = Cold plate technique
Power e.g.
251 = 25 x 101 W = 0.25 kW
222 = 22 x 10
Voltage class
2 = 230/240 V, 1/N/PE AC (0.25 ... 2.2 kW)
4 = 400/500 V, 3/PE AC (0.37 ... 22 kW)
Ambient conditions
S = standard industrial environment IE33 according to IEC 60721−3−3
V = rough environment (coated printed circuit boards)
Safety technology
X = without safety technology
B = with drive−based safety "safe torque off (STO)"
22
efesotomasyon.com - Lenze
E84
2
W = 2.2 kW
l
A
V
xx
x
xxx
x
x
x
0
EDS84ASC552 EN 6.0