Mechanical Installation; Important Notes - Lenze 8400 StateLine C Hardware Manual

L-force drives frequency inverter
Hide thumbs Also See for 8400 StateLine C:
Table of Contents

Advertisement

5

Mechanical installation

5.1

Important notes

{
Danger!
Sticker with warning note must be displayed prominently and close to the
device!
)
Note!
The devices must be installed in housings (e.g. control cabinets) to meet
applicable regulations.
If the cooling air is polluted (fluff, (conductive) dust, soot, aggressive gases), take
ƒ
adequate countermeasures, as e.g.:
– Separate air guide
– Installation of filters
– Regular cleaning
Possible mounting position:
ƒ
– Vertical on the mounting plate (mains connections at the top, motor connection at
the bottom)
Maintain the specified free spaces above and below the controller to other
ƒ
installations!
– Ensure unimpeded ventilation of cooling air and outlet of exhaust air.
– You can install several controllers of the 8400 L−force Inverter Drives product range
next to each other without any clearance in the control cabinet.
The mounting plate of the control cabinet must be electrically conductive.
ƒ
In case of continuous vibrations or shocks use vibration dampers.
ƒ
EDS84ASC552 EN 6.0
efesotomasyon.com - Lenze
Mechanical installation
l
Important notes
5
61