5
Mechanical installation
Standard devices in the power range 0.25 ... 2.2 kW
Assembly in push−through technique (thermal separation)
5.2.2
Assembly in push−through technique (thermal separation)
The E84AVxxD... controllers are designed for mounting in push−through design. The scope
of supply includes all parts required for mounting.
Installation steps
How to proceed:
1. Prepare mounting cutout and mounting holes (threaded holes M5 recommended).
2. Insert the 8400 frequency inverter into the mounting cutout.
3. Tighten with 6 screw and washer assemblies M5 x 10 (cross screw connection
recommended).
4. Seal the screws to ensure the IP54 enclosure or UL type 12.
Fig. 5−4
E84AVxxD2512
E84AVxxD3712
E84AVxxD3714
E84AVxxD551x
E84AVxxD751x
E84AVxxD112x
E84AVxxD152x
E84AVxxD222x
68
efesotomasyon.com - Lenze
Dimensions: Mounting in push−through technique
a
b
[kW]
[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [kg]
0.25 ...
102
226
185
0.37
0.37 ...
102
276
163
0.75
1.1 ... 2.2
137
335
163
l
c
c1
c2
d1
d2
205
14
80
85
183
36
105
110
183
60
135
135
8400SLC046
e
f
g
h
74.6
170.2
90
12
1.4
± 1
± 1
74.6
220.5
90
12
1.9
± 1
± 1
108.7
273.5
125
12
3.5
± 1
± 1