7.2.1

Keypad control

Step−by−step commissioning
1. Wiring of power terminals
Make use of the chapter "Electrical installation" or the Mounting Instructions to wire the
power terminals according to the requirements of your device.
2. Wiring of control terminals.
– StateLine
Digital inputs at terminal X4
X4
GIO
DO1
DI4
– HighLine
Digital inputs at terminal X5
X5
GI
DI7
DI6
3. Load Lenze setting to controller
)
Note!
The application "actuating drive speed" is implemented with the Lenze
setting.
Par1 8400 StateLineC
User - Menu
Code list
Quick commissioning
SAVE
EDS84ASC552 EN 6.0
efesotomasyon.com - Lenze
DI3
DI2
DI1
RFR
24I
24E
DI5
DI4
DI3
DI2
DI1
RFR
24I
24E
Par1 Quick commissioning
Terminals
Keypad
SAVE
l
Commissioning
Quick commissioning
Keypad control
Assignment
Information
RFR
l
Controller enable
RFR = High
l
Reset error
High ® Low (edge−controlled)
Assignment
Information
RFR
l
Controller enable
RFR = High
l
Reset error
High ® Low (edge−controlled)
After attaching the keypad or
MCTRL: Act. speed val.
C00051
switching on the controller with
keypad attached, the connection
0 rpm
between keypad and controller is
established.
The connection has been established
when the code C00051 appears in
the display.
l
l
Load Lenze setting
C00002/1
l
l
l
EDIT
l
Then press the left function key.
Starting from "User menu" scroll
down with button to "Quick
commissioning" menu
Click right button.
Select "Keypad" menu.
Click right button.
Code 00002/1:
– Parameterise with left "Edit"
function key
– Select value "1"− −> On/Start
and confirm with right "OK"
function key.