Digital Inputs And Outputs - Lenze 8400 StateLine C Hardware Manual

L-force drives frequency inverter
Hide thumbs Also See for 8400 StateLine C:
Table of Contents

Advertisement

6.7.3

Digital inputs and outputs

X5
Fig. 6−33
Labelling
RFR
DI1
DI2
DI3
DI4
DI5
DI6
DI7
GI
Terminal data
flexible
with wire end ferrule
EDS84ASC552 EN 6.0
efesotomasyon.com - Lenze
Connection of the digital inputs
Description
Controller enable/controller inhibit, always required
^ 59
Digital input 1
IEC61131−2, type 1 or two−track frequency input, for HTL
Digital input 2
encoder 0 ... 100 kHz
Digital input 3
^ 59
Digital input 4
IEC61131−2, type 1
Digital input 5
Digital input 6
IEC61131−2, type 1 or
two−track frequency input for HTL encoder 0 ... 10 kHz
Digital input 7
GND digital inputs
Conductor cross−section
2
[mm
]
0.2 ... 1.5
l
Electrical installation
HighLine C control terminals
Digital inputs and outputs
GND-I
DI6
DI5
X5
GI
DI7
DI4
8400HLC036
Tightening torque
[AWG]
[Nm]
24 ... 16
24 V int.
DI3
RFR
24I
DI2
DI1
24E
DC 24 V
S1
(+19.2...
+28.8 V)
8400HLC045
track A
track B
!
[lb−in]
2.5 x 0.4
137