Diagnostics; Display Of Operating Data, Diagnostics; Status Display Via Leds At The Controller - Lenze 8400 StateLine C Hardware Manual

L-force drives frequency inverter
Hide thumbs Also See for 8400 StateLine C:
Table of Contents

Advertisement

9

Diagnostics

9.1

Display of operating data, diagnostics

9.1.1

Status display via LEDs at the controller

During operation, the operating status of the controller is indicated by four light−emitting
diodes.These are located at the front of the device. The upper two LEDs indicate the current
status of the CAN bus connection and the lower two LEDs indicate the status of the
controller.
LED
CAN-RUN
CAN-ERR
DRV-RDY
DRV-ERR
Legend
The symbols used for indicating the LED states have the following meaning:
EDS84ASC552 EN 6.0
efesotomasyon.com - Lenze
Display of operating data, diagnostics
Status display via LEDs at the controller
Labelling
Colour
CAN−RUN
green
CAN−ERR
red
DRV RDY
green
DRV ERR
red
8400SLC026
LED flashes once approx. every 3 seconds (slow flash)
LED flashes once approx. every 1.25 seconds (flash)
LED flashes twice approx. every 1.25 seconds (double flash)
LED blinks every second
LED is permanently on
l
Diagnostics
Description
CAN−BUS o.k.
CAN−BUS error
Controller is ready for operation
Error in the controller or through the application
9
163

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

8400 highline c

Table of Contents