Assembly In Push−Through Technique (Thermal Separation) - Lenze 8400 StateLine C Hardware Manual

L-force drives frequency inverter
Hide thumbs Also See for 8400 StateLine C:
Table of Contents

Advertisement

5.3.2
Assembly in push−through technique (thermal separation)
The E84AVxxD... controllers are designed for mounting in push−through design. The scope
of supply includes all parts required for mounting.
Installation steps
How to proceed:
1. Prepare mounting cutout and mounting holes (threaded holes M5 recommended).
2. Insert the 8400 frequency inverter into the mounting cutout.
3. Tighten with 6 screw and washer assemblies M5 x 10 (cross screw connection
recommended).
4. Seal the screws to ensure the IP54 enclosure or UL type 12.
Fig. 5−9
E84AVxxD3024
E84AVxxD4024
E84AVxxD5524
EDS84ASC552 EN 6.0
efesotomasyon.com - Lenze
Standard devices in the power range 3 ... 22 kW
Assembly in push−through technique (thermal separation)
Dimensions: Assembly in push−trough technique for devices in the power range 3 ... 5.5kW
a
b
[kW]
[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]
3 ... 5.5
174
366
l
Mechanical installation
c
c1
c2
d
141
161
64
300
8400HLC073
e
f
g
h
145.2
277.2
160
15
± 1
± 1
5
[kg]
4.9
77