1.5.3.3

Default settings for the sampling times

When commissioning for the first time, the current controller sampling times (p0115[0]) are
automatically pre-set with factory setting values:
Table 1- 13
Factory settings
Construction type
Active Infeed
Booksize
Chassis
400 V / ≤ 300 kW
690 V / ≤ 330 kW
Chassis
400 V / > 300 kW
690 V / > 330 kW
Smart Infeed
Booksize
Chassis
400 V / ≤ 355 kW
690 V / ≤ 450 kW
Chassis
400 V / > 355 kW
690 V / > 450 kW
Basic Infeed
Booksize
Chassis
Servo
Booksize
Chassis
Blocksize
Vector
Booksize
Chassis
400 V / ≤ 250 kW
Booksize
Chassis
400 V / ≤ 250 kW
Chassis
> 250 kW
690 V
Caution
If a Power Module in blocksize format is connected to a Control Unit, the sampling times of all vector drives are set
according to the rules for Power Modules in blocksize format (only 250 µs or 500 µs possible).
Commissioning Manual
Commissioning Manual, (IH1), 01/2012, 6SL3097-4AF00-0BP2
Number
1
1
1
1
1
1
1
1
1
1
1
1
1 to 6
1 to 6
1 to 5
1 to 3 only n_ctrl
1 to 6 only U/f
4 to 12
1 to 4 only n_ctrl
1 to 5 only U/f
1 to 6 only n_ctrl
p0112
2 (Low)
250 µs
2 (Low)
250 µs
2 (Low)
250 µs
0 (Expert)
375 µs (p0092 = 1)
1 (xLow)
400 µs (p0092 = 0)
2 (Low)
250 µs
2 (Low)
250 µs
2 (Low)
250 µs
2 (Low)
250 µs
2 (Low)
250 µs
4 (High)
250 µs
3 (Standard)
2000 µs
3 (Standard)
125 µs
1 (xLow)
250 µs
3 (Standard)
125 µs
3 (Standard)
250 µs
0 (Expert)
500 µs
0 (Expert)
375 µs (p0092 = 1)
1 (xLow)
400 µs (p0092 = 0)
0 (Expert)
500 µs (p0092 = 1)
Preparation for commissioning
1.5 Rules for wiring with DRIVE-CLiQ
p0115[0]
-
-
-
-
-
-
-
-
-
-
-
-
4 kHz
2 kHz
4 kHz
4 kHz
2 kHz
4 kHz
2 kHz
1.333 kHz
1.25 kHz
2 kHz
p1800
37