Siemens SINAMICS S120 Commissioning Manual page 177

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

CU310-2 DP / CU310-2 PN
The Control Unit 310-2 has an integrated SMC30 encoder interface. This encoder interface
is accessed via the 15-pin Sub-D-contact X23 and is evaluated as temperature channel 1.
There are three options available to evaluate the temperature:
1. Temperature channel 1 via the SMC30 encoder interface X23.
2. Temperature channel 1 via terminal X120, for example, if an encoder is being used.
3. Two temperature channels via X23 and X120. Encoder interface X23 is assigned to
The following parameter settings must be made:
For 1. One temperature channel 1 via encoder interface X23:
● p0600[0..n] = 1: Selects the encoder (1, 2 or 3), which is assigned to encoder interface
● p0601[0..n] = 1 or 2: Selection of the temperature sensor type, n = motor data set
● r0035: Display of the temperature value.
For 2. One temperature channel 1 via terminal X120:
● p0600[0..n] = 11: Activation from temperature channel 1 via terminal X120
● p0601[0..n] = 1 or 2: Selection of the temperature sensor type, n = motor data set
● r0035: Display of the temperature value.
For 3. Two temperature channels via X23 and X120:
● p0600[0..n] = 1: Selects the encoder (1, 2 or 3), which is assigned to encoder interface
● p0601[0..n] = 10: Evaluation via several temperature channels
● p4600[0..n]: Selection of the temperature sensor type from temperature channel 1, n =
● p4601[0..n]: Selection of the temperature sensor type from temperature channel 2, n =
● r4620[0...3]: Reading the temperature values.
● r0035: Display of the higher temperature value of temperature channels 1 and 2.
CUA31
The parameterization of the temperature evaluation via terminal X210 can be performed
using the STARTER screen (signals and monitoring \ motor temperature). "Temperature
sensor via Motor Module (11)" should be selected in the "Temperature sensor selection"
field. The temperature of the sensor is displayed in r0035.
Commissioning Manual
Commissioning Manual, (IH1), 01/2012, 6SL3097-4AF00-0BP2
temperature channel 1 and terminal X120 is assigned to temperature channel 2.
X23 and via which the temperature is evaluated (n = motor data set).
X23 and via which the temperature is evaluated (n = motor data set).
encoder data set
encoder data set
– Index n = 0 temperature channel 1
– Index n = 1 temperature channel 2
2.16 Temperature sensors for SINAMICS components
Commissioning
175

Advertisement

Table of Contents
loading

Table of Contents