Siemens SINAMICS S120 Commissioning Manual page 107

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

What to do?
7.
Save the
parameters on the
device
8.
The motor starts to
run.
STARTER diagnostic options
Under Component -> Diagnostics -> Control/status words
● Control/status words
● Status parameters
● Missing enable signals
Commissioning Manual
Commissioning Manual, (IH1), 01/2012, 6SL3097-4AF00-0BP2
1. Call the menu "Project" > "Connect to selected target devices"
(online mode).
2. Call the menu "Target system > Load > Load CPU/drive unit
to target device...".
1. Select the drive unit in the project tree.
2. Call the menu "Target system > Copy RAM to ROM".
(save the data on the memory card)
The drives can be started via the control panel in STARTER.
The control panel can be found in the project tree under "Drive
unit \ Drives \ Commissioning \ Control panel".
2.5 First commissioning, servo control mode, booksize format
How to do it?
Commissioning
Comment
Left-click on the drive unit
(SINAMICS S120)
For more information about
the control panel, see
Getting Started.
The control panel supplies
the control word 1 (STW1)
and speed setpoint 1
(NSOLL).
For more information about
line/DC link identification,
see the SINAMICS S120
Function Manual.
105