Commissioning
2.13 Commissioning linear motors (servo)
2.13.2
Commissioning: Linear motor with one primary section
Commissioning with STARTER
Linear drives can achieve significantly higher rates of acceleration and velocities than
conventional drives.
The traversing range must always be kept clear in order to avoid any potential danger for
man or machine.
Commissioning the motor with STARTER
1. Selecting the motor type
156
DANGER
You can select a standard motor from the list of motors. You can enter the motor data for
third-party motors manually. The number of parallel primary sections (p0306) must be
entered.
Figure 2-37
STARTER screen, linear motor selection 1FN3
Commissioning Manual, (IH1), 01/2012, 6SL3097-4AF00-0BP2
Commissioning Manual