Mitsubishi Electric GOT2000 Series Connection Manual page 135

Graphic operation terminal (non-mitsubishi electric products 2)
Hide thumbs Also See for GOT2000 Series:
Table of Contents

Advertisement

(d)
Setting of Transmission speed, Stop bit, Data bit, Parity bit, Initializing method
Make the settings using the character configuration switches.
Setting item
Transmission speed
Stop bit
Data bit
Parity bit
Initializing method
■4. Connecting to FFK120A-C10
(1) Communication settings
Make the communication settings using setting switches.
*4
MODE
*1
Transmission speed
*1
Data bit
*1
Parity bit
*1
Stop bit
Initializing method
*1*2
Station No.
*3
Terminating resistor
T-link channel switch
T-link terminating resistor
*1
Adjust the settings with GOT settings.
*2
Avoid duplication of the station No. with any of the other units.
*3
Turn ON the terminating switch of a general-purpose interface module which will be a terminal.
*4
Set as necessary.
Set value
9600bps
19200bps
1bit
2bits
7bits
8bits
Even
Odd
Done
None
By switch
Item
Command-setting-type start-stop synchronization, nonsequence format
RS-232C 1:1
Command-setting-type start-stop synchronization, nonsequence format
RS-232C 1:1,
and RS-485 1:N
Command-setting-type start-stop synchronization, nonsequence format
RS-485 1:N
9600bps, 19200bps
8bits or 7bits
Even or Odd
Done, None
1bit, 2bits
By switch
0 to 99
ON or OFF
8
7
6
5
4
3
2
1
ON
Switch No.
1
2
3
4
ON
OFF
ON
OFF
ON
ON
ON
OFF
Set value
FUJI PLC user's Manual
4.2 Serial connection
5
6
7
8
ON
OFF
ON
OFF
ON
OFF
ON
4 - 27
4

Advertisement

Table of Contents
loading

Table of Contents