Specifications - Chroma 63610-80-20 Operation & Programming Manual

Programmable dc electronic load
Table of Contents

Advertisement

Programmable DC Electronic Load 63600 Series Operation & Programming Manual
(0.8 V).
Selective voltage and current ranges.
Remote sensing capability.
100 sets of memories to save/recall user-definable setups.
10 sets of programs to link files for automatic test.
16-bit A/D converter with precision measurement.
Short circuit simulation.
Master/Slave parallel control mode, allow synchronous load control under static and
dynamic loading mode
Automatic GO/NG inspection to examine if UUT within spec.
Independent GO/NG signals for each channel.
Protection Over voltage, Over current, Overpower, Over temperature, Reverse polarity.
1.4

Specifications

Mainframe:
AC input range:
Fuse:
Frequency:
Maximum VA:
Weight:
Dimension:
Width:
Height:
Depth:
Mainframe:
AC input range:
Fuse:
Frequency:
Maximum VA:
Weight:
Dimension:
Width:
Height:
Depth:
The detail specifications of Load are listed in the next page.
This equipment is not intended for performing measurements on CAT II,
CAUTION
III or IV.
1.
2.
3.
4.
5.
1-6
63600-5
1φ 100~115VAC ±10%V
1φ 200~230VAC ±10%V
5A, 250V
47 to 63 Hz
300VA
15.6kg / 34.39lbs
447 mm / 17.6 inch
177 mm / 7.0 inch (without foot stand)
194.8 mm / 7.7 inch (with foot stand)
554.2 mm / 21.8 inch (with Load Module)
63601-5
1φ 100~240VAC ±10%V
10A, 250V
47 to 63 Hz
1000VA
13.6kg / 29.98lbs.
447 mm / 17.6 inch
177 mm / 7.0 inch (without foot stand)
194.8 mm / 7.7 inch (with foot stand)
554.2 mm / 21.8 inch (with Load Module)
The equipment is for indoor use only.
The altitude up to 2,000 meters is allowed to use the equipment.
All specifications are tested under 20°C ∼ 30°C except otherwise
stated.
The range of operation temperature is 0°C ∼ 40°C.
The relative humidity is from 10% to 90%. When in high humidity
Auto range
LN
Auto range
LN
LN

Advertisement

Table of Contents
loading