7.3.5.1 Checking Dynamic Constant Current High Range
MODE
A.
First, press
indicator.
EDIT
B.
Press
to enter into Dynamic Constant Current setting. The settings are listed in
Table 7-17.
C.
Set the DC Source output voltage to 5V (hint: Set to 7V for Model 63630-600-15), the
limit current needs to be larger than the highest level set by dynamic constant current.
(EX: When the 63630-600-15 H level is set to 15A, the DC Source limit current can set
to 17A.)
When the 63640-150-60 is doing dynamic loading, the minimum working
voltage should be larger than 2.5V.
Model
63630-600-15
63640-150-60
63630-80-60
63610-80-20
63640-80-80
7.3.5.2 Checking Dynamic Constant Current Medium Range
MODE
A.
First, press
indicator.
EDIT
B.
Press
to enter into Dynamic Constant Current setting. The settings are listed in
Table 7-18.
C.
Set the DC Source output voltage to 5V and the limit current needs to be larger than the
highest level set by dynamic constant current. (EX: When the 63630-600-15 H level is
set to 1.5A, the DC Source limit current can set to 2A.)
Model
63630-600-15
63640-150-60
63630-80-60
63610-80-20
63640-80-80
till VFD shows CC and press
Table 7-17
H
L
15A
0A
60A
1A
60A
0A
20A
0A
80A
0A
till VFD shows CC and press
Table 7-18
H
L
1.5A
0A
6A
0A
6A
0A
2A
0A
8A
0A
RANGE
to light up the H range LED
T1
T2
10ms
10ms
10ms
10ms
10ms
10ms
10ms
10ms
10ms
10ms
RANGE
to light up the M range LED
T1
T2
10ms
10ms
10ms
10ms
10ms
10ms
10ms
10ms
10ms
10ms
Verification
SR/
SR\
1.5 A/μs
1.5 A/μs
6 A/μs
6 A/μs
6 A/μs
6 A/μs
2 A/μs
2 A/μs
8 A/μs
8 A/μs
SR/
SR\
0.15 A/μs 0.15 A/μs
0.6 A/μs
0.6 A/μs
0.6 A/μs
0.6 A/μs
0.2 A/μs
0.2 A/μs
0.8 A/μs
0.8 A/μs
7-13