External Waveform Control; Voltage & Current Monitor - Chroma 63610-80-20 Operation & Programming Manual

Programmable dc electronic load
Table of Contents

Advertisement

Programmable DC Electronic Load 63600 Series Operation & Programming Manual
00~99) set by the 7-segament digit display on the Mainframe panel and then press RECALL
to recall the saved settings.

3.19 External Waveform Control

The external dynamic test, operated in the CC mode, is similar to that under the Dynamic
test, but the load level switching is controlled by the duty cycle of an External signal. It works
the same way as the dynamic test except that the Period control signals are not generated
internally, but are inputted from V EXT. Connectors are on the rear panel. A 0-to-10V
external signal corresponds to the 0-to-full scale input range, so that users should apply DC
offset for the external signal in the range from 0 to 10V. For the configuration of external
waveform control usage, refer to section 4.7.1 for details.
3.20 Voltage & Current Monitor
Each channel of the Load has two isolated connectors to monitor load voltage and current,
the output signal to I MON and V MON. Connectors are on the rear panel. A 0-to-10V output
signal corresponds to the 0-to-full scale load V&I range.
3-24

Advertisement

Table of Contents
loading

Table of Contents