Chroma 63610-80-20 Operation & Programming Manual page 105

Programmable dc electronic load
Table of Contents

Advertisement

In the page of Advance function, turn the Rotary knob to change the display value to 4, then
ENTER
press
key into the page of Program Sequences Function, the VFD displays Program
Sequences Function.
EDIT
Press the
key to enter into the editing mode. Then, press
setting parameter.
1.
Setting the Number of Program.
There are ten programs (1-10) and up to 100 sequences can be set. Turn the Rotary
knob to change the display value to 1, then press
2.
Setting Type of program.
There are two types of program: List and Step. Turn the Rotary knob to change the type
until the desired type is displayed on the VFD. Then, press
and confirm the setting.
3.
Setting the Program Chain
The chain function of program enables you to chain program so as to get more
sequences for testing. Set program chain number to 0 means no program chain.
Program chain function can chain itself for loop test, or chain other programs. Turn the
Rotary knob to change the display value to 1, then press
loop test. The default setting is 0.
4.
Set Repeat Times.
Set the repeat times of the Program Chain. Turn the LOAD Rotary to change the
Repeat times as desired. Then, press
5.
Display the Remain Unsetting Sequence Amount.
The Load shows the Remain Unsetting Sequence amount, which is from total 100
Sequences subtracting the amount of the total setting Sequences.
[ AUTO SEQUENCES ]
0 . 0 0 0 0
V
0 . 0 0 0 0
A
PROG: 01
TYPE: LIST
CHAIN: 1
ENTER
key to confirm the setting.
REPEAT: 1
DATA
to select the
ENTER
key to confirm the setting.
ENTER
key to select type
ENTER
to set chain itself for
Local Operation
4-29

Advertisement

Table of Contents
loading

Table of Contents