Setting Parameters:Refer to respective specification for valid value range.
Setting Example:
Query Syntax:
Return Parameters:<NR2>, [Unit = Volt]
Query Example:
VOLTage:STATic:L2
Type:
Description:
Setting Syntax:
Setting Parameters:Refer to respective specification for valid value range.
Setting Example:
Query Syntax:
Return Parameters: <NR2>, [Unit = Volt]
Query Example:
VOLTage:STATic:TYPE
Type:
Description:
Setting Syntax:
Setting Parameters:<NRf>, CURR/PSU(0), VOLT/PSU(1)
Example:
Query Syntax:
Return Parameters:<CRD>, CURR/PSU, VOLT/PSU
Query Example:
VOLTage:STATic:RESponse
Type:
Description:
Setting Syntax:
Setting Parameters:<NRf>, FAST(0), NORMAL(1), SLOW(2)
Example:
Query Syntax:
Return Parameters:<CRD>, FAST, NORMAL, SLOW
Query Example:
VOLT:STAT:L1 8
VOLT:STAT:L1 24V
VOLT:STAT:L1 MAX
VOLT:STAT:L1 MIN
VOLTage:STATic:L1?[<space><MAX | MIN>]
VOLT:STAT:L1?
VOLT:STAT:L1? MAX
VOLT:STAT:L1? MIN
Channel-Specific
Set the static load voltage in constant voltage mode.
VOLTage:STATic:L2<space><NRf+>[suffix]
VOLT:STAT:L2 8
VOLT:STAT:L2 24V
VOLT:STAT:L2 MAX
VOLT:STAT:L2 MIN
VOLTage:STATic:L2?[<space><MAX | MIN>]
VOLT:STAT:L2?
VOLT:STAT:L2? MAX
VOLT:STAT:L2? MIN
Channel-Specific
Set the execution type in constant voltage mode.
VOLTage:STATic:TYPE<space><NRf>
VOLT:STAT:TYPE CURR/PSU
VOLT:STAT:TYPE 1
VOLTage:STATic:TYPE?
VOLT:STAT:TYPE?
Channel-Specific
Set the response speed in constant voltage mode.
VOLTage:STATic:RESponose<space><NRf>
VOLT:STAT:RES FAST
VOLT:STAT:RES SLOW
VOLTage:STATic:RESponse?
VOLT:STAT:RES?
Set voltage of load L1 as 8V.
Set voltage of load L1 as 24V.
Set voltage of load L1 as the
maximum value.
Set voltage of load L1 as the minimum
value.
Set voltage of load L2 as 8V.
Set voltage of load L2 as 24V.
Set voltage of load L2 as the
maximum value.
Set voltage of load L2 as the minimum
value.
Remote Operation