Chroma 63610-80-20 Operation & Programming Manual page 141

Programmable dc electronic load
Table of Contents

Advertisement

STEP 5:
Once the setting is done, click OK to return to previous level and click OK again to exit and
finish the setting procedure.
Steps to set DHCP = OFF for Chroma DC Load 63600:
STEP 1:
When DHCP=OFF, it also needs to set IP, GATEWAY and SUBNET MASK parameters. If
the network parameters are already set on user's computer or other devices in the network,
users can enter SUBNET MASK, GATEWAY settings to 63600 directly while setting a
different IP address for 63600. For instance the computer IP is 10.1.7.100, Mask is
255.255.254.0 and Gateway is 10.1.7.254, then users can set the IP to 10.1.7.101, Mask to
255.255.254.0 and Gateway to 10.1.7.254 for 63600 under the premise that the IP:
10.1.7.101 has not been used by any other users.
STEP 2:
ENTER
DATA
Press
or
setting.
STEP 3:
The screen will show the networking setting status. The status messages are shown below:
a.
Initiating...
b.
Connecting...
c.
Disconnection!
d.
DHCP Failure!!
directly to go to APPLY option and set it to YES, then confirm the
: The network card is initialing.
: The network card is connecting.
: It is unable to connect to network.
: It cannot find DHCP Server and is unable to specify the IP
Remote Operation
5-9

Advertisement

Table of Contents
loading

Table of Contents