Programmable DC Electronic Load 63600 Series Operation & Programming Manual
Setting Syntax:
Setting Parameters: <NR2>, [Unit=A/μs]
Example:
CDF
Type:
Description:
Setting Syntax:
Setting Parameters: <NR2>, [Unit=A/us]
Example:
CDRT
Type:
Description:
Setting Syntax:
Setting Parameters: <NR1>, 0 ~ 65535
Example:
L
Type:
Description:
Setting Syntax:
Setting Parameters: <NR2>
Example:
SRA
Type:
Description:
Setting Syntax:
Setting Parameters: <NR1>, 1: RESET, Other Value: no action
Example:
5-96
channels in one frame. The frame will ignore the setting if the
channel does not exist.
CDR<space>"n,n,n,n,n,n,n,n,n,n"
CDR "1.0,2.5,2.5,10,2.0,5.0,5.0,5.0,0,0"
All Channels
Set the falling slew rate of CCDL/CCDM/CCDH mode to the ten
channels in one frame. The frame will ignore the setting if the
channel does not exist.
CDF<space>"n,n,n,n,n,n,n,n,n,n"
CDF "1.0,2.5,2.5,10,2.0,5.0,5.0,5.0,0,0"
All Channels
Set the repeat count of CCDL/CCDM/CCDH mode to the ten
channels in one frame. The frame will ignore the setting if the
channel does not exist.
CDRT<space>"n,n,n,n,n,n,n,n,n,n"
CDRT "1,2,2,10,2,5,5,5,0,0"
All Channels
Set the load level according to mode setting for the ten channels in
one frame. The frame will ignore the setting if the channel does not
exist.
L<space>"n,n,n,n,n,n,n,n,n,n"
[Unit=Ampere(CCL/CCM/CCH)]
[Unit=OHM(CRL/CRM/CRH)]
[Unit=Volt(CVL/CVM/CVH)]
[Unit=Watt(CPL/CPM/CPH)]
L "1.0,2.5,2.5,10,2.0,5.0,5.0,5.0,0,0"
All Channels
This command resets the Von control signal to initial state for the
ten channels in one frame. The frame will ignore the setting if the
channel does not exist.
SRA<space>"n,n,n,n,n,n,n,n,n,n"
SRA "0,0,1,1,1,1,1,0,0,0"