7.3.2.3 Checking Low ohm Range

MODE
A.
Press
till VFD shows CR and press
indicator.
B.
The current shunt range is 250A. Press
LOAD
7-10 . Press
source same as the setting value for testing model before, and waited for 30 seconds,
record the voltage that passes through the load input terminals DMM (V) and the shunt
current reading DMM (I). Calculate the values of the resistance via DMM (V)/DMM (I).
Check the values to fit the specification.
Model Name
Resistance
63630-600-15
63640-150-60
63630-80-60
63610-80-20
63640-80-80

7.3.3 CV Mode Verification

This test verifies if the voltage programming and reading value on the front panel display are
within specifications when the module is operating in CV mode. For each DMM (V) reading,
the front panel display of voltage should be equivalent to:
Load module reading in volts = DMM (V) reading in volts ± inaccuracy.

7.3.3.1 Checking High Voltage Range

A.
Connect the Load module, DC source, DMM and current shunt as Figure 7-1 shows.
Use DMM (V) to measure the voltage passing through the module's input terminal. Be
careful in making connections so that contact resistance voltage drop will not affect the
readings.
MODE
B.
Press
till VFD shows CV and press
indicator.
EDIT
C.
Press
to set load voltage and press
voltage output and limit current settings are based on the voltage/current values listed in
Table 7-11.
LOAD
D.
Next, press
passing through the negative input terminal.
to enable load, and see value of DMM(V) to adjust the value of DC
Table 7-10
Input Value of
Setting
DC Source
270Ω
80V
0.133Ω
2V
60Ω
12V
0.2Ω
8V
30Ω
6V
0.015Ω
0.8V
80Ω
6V
0.04Ω
0.8V
20Ω
6V
0.01Ω
0.8V
to enable the load and wait for 30 seconds to record the voltage
RANGE
to light up the L range LED
EDIT
to input the resistance listed in Table
Appropriate
Max.
0.02371S
7.546316S
0.067S
5.072S
0.233367S
66.9333S
0.087513S
25.1S
0.32505S
100.375S
RANGE
to light up the H range LED
DATA
to set limit current. The DC Source
Verification
Conductance (S)
Min.
0S
7.491278S
0S
4.928S
0S
66.4S
0S
24.9S
0 S
99.625S
7-7