Programmable DC Electronic Load 63600 Series Operation & Programming Manual
7.3.5.3 Checking Dynamic Constant Current Low Range
MODE
A.
First, press
indicator.
EDIT
B.
Press
to enter into Dynamic Constant Current setting. The settings are listed in
Table 7-19.
C.
Set the DC Source output voltage to 5V and the limit current needs to be larger than the
highest level set by dynamic constant current. (EX: When the 63630-600-15 H level is
set to 0.15A, the DC Source limit current can set to 0.5A.)
Model
63630-600-15
63640-150-60
63630-80-60
63610-80-20
63640-80-80
7-14
till VFD shows CC and press
Table 7-19
H
L
150mA
0A
0.6A
0A
0.6A
0A
0.2A
0A
0.8A
0A
Figure 7-3
RANGE
to light up the L range LED
T1
T2
10ms
10ms
10ms
10ms
10ms
10ms
10ms
10ms
10ms
10ms
SR/
SR\
15m A/μs 15m A/μs
0.06 A/μs 0.06 A/μs
0.06 A/μs 0.06 A/μs
0.02 A/μs 0.02 A/μs
0.08 A/μs 0.08 A/μs
Need help?
Do you have a question about the 63610-80-20 and is the answer not in the manual?