Select None / Master / Slave for parallel mode. Set the specified module to none, master
or slave for parallel run.
NONE:
Disable the MASTER/SLAVE control function.
MASTER:
Used as the master for the parallel group and this is the only one controlled by
front panel or PC in this group. Also tell the slaves how many current they
should sink. Slave Model: 1 – 5 to setup the slave's model to use in parallel.
NONE means not exist.
SLAVE:
Setup the load as slave.
To leave out of the Parallel edit page of system configuration, you need to press
ENTER
simultaneously to go back to the page of system configuration.

4.7.5 Setup of Synchronous Dynamic Mode

The following is Operation Flow:
NONE
When Synchronous Dynamic Mode is set to ON, the Load on/off is controlled by
on the any module of the Mainframe. Under other circumstances the Load on/off is
individually and simply controlled by
In the page of system configuration, turn the Rotary knob to change the display value to 5,
ENTER
then press
key into Synchronous Dynamic Mode page of system configuration.
Select None / Master / Slave for Synchronous Dynamic Mode. Set the specified module
[PARALLEL MODE]
MODE
: MASTER
INITIAL
: OFF
CONFIG
SYNC.
Mode
Mode?
MASTER
LOAD
key on the module.
Local Operation
ADVA
and
SLAVE
LOAD
key