Chroma 63610-80-20 Operation & Programming Manual page 127

Programmable dc electronic load
Table of Contents

Advertisement

6
TRIG_SEQ
7
TRIG_DIGI
8
LOAD_ON
9
DO1
10
DI1
11
AGNDC
12
EXT_WAVE2
13
EXT_WAVE1
14
AGNDC
15
EXT_WAVE6
16
EXT_WAVE5
17
AGNDC
1. TTL High Level Voltage is 5V。
2. SHORT [1:10]: Short ON output signals from the first channel to the
tenth channel, TTL Level, Active High.
3. TRIG_ SEQ: External trigger input signal used to increment get to
the next sequence setting. TTL Level, falling edge, pulse width ≥1μs.
4. TRIG_DIGI: External trigger input signal to be the trigger Source of
Digitizing Function. TTL Level, falling edge, pulse width ≥1μs
5. LOAD_ON: Load ON output signal, TTL Level, Active High.
6. DI [1:2]: 2 bits of digital input signals, TTL Compatible.
DI1 and DI2 have External Load ON/OFF function. The user can use
this input signal to control the Load ON/OFF externally. If DI1 and
DI2 are set to External Load ON/OFF, the two signals need to be
HIGH to become Load OFF and vice versa both of the signals need
to be LOW to become Load ON.
When DI1 (or DI2) is set to Remote Inhibit and is Low, all channels in
FRAME are Load off and a REMOTE INHIBIT protection message
will appear. Load on will not be active if the protection message of
REMOTE INHIBIT is not cleared even though the DI1 (or DI2) is
High.
7. DO [1:2]: 2 bits of digital output signals, High Level: 4.7kΩ resistor
pull up to 1.8V/3.3V/5V selectable, Low Level <0.6V, sink current =
10mA.
DO1 and DO2 have the following 5 functions available for selection:
a. OCP TEST PASS-H: In OCP mode, if the test result is Pass, the
b. OCP TEST FAIL-L: In OCP mode, if the test result is Fail, the
c. GONG TOTAL PASS-H: When the SPEC is ON, if all channels
d. GONG TOTAL FAIL-L: When the SPEC is ON, if all channels
e. OTP OVP OCP OPP REV-H: If the load has any one of the
The selections of DOUT_VOLT are:
a. NONE: It sets the Dout High level to floating.
b. 1.8V: It sets the Dout High level to 1.8V.
c. 3.3V: It sets the Dout High level to 3.3V.
40
DGNDC
41
DGNDC
42
DGNDC
43
DO2
44
DI2
45
AGNDC
46
AGNDC
47
EXT_WAVE4
48
EXT_WAVE3
49
AGNDC
50
EXT_WAVE8
51
EXT_WAVE7
DO will output HIGH level signal, or it remains at LOW level.
DO will output LOW level signal, or it remains at HIGH level.
are determined as Good, the DO will output HIGH level signal,
or it will remain at LOW level.
are determined as No Good, the DO will output LOW level
signal, or it will remain at HIGH level.
OTP, OVP, OCP, OPP, REV protection, the DO will output
HIGH level signal, or it will remain at LOW level.
23
VMON4
24
IMON4
25
AGNDC
26
VMON6
27
IMON6
28
AGNDC
29
VMON8
30
IMON8
31
AGNDC
32
VMON10
33
IMON10
34
AGNDC
Local Operation
57
AGNDC
58
VMON3
59
IMON3
60
AGNDC
61
VMON5
62
IMON5
63
AGNDC
64
VMON7
65
IMON7
66
AGNDC
67
VMON9
68
IMON9
4-51