Programmable DC Power Supply (with Solar Array Simulation) 62000H Series
Operating & Programming Manual
1.2.3

Output/Indication

(1) Auxiliary power output (12Vdc/10mA).
(2) Analog monitors (V/I) continuously send an output signal. This allows signals to be easily
monitored by external instruments (DMM, Oscilloscope, etc.). Ability to set the output
level indication (DC ON) signal.
(3) Output indicator (DC ON) signal.
(4) Protection state indication (OVP/OCP/OPP /FAN LOCK/AC FAULT, etc.).
(5) Over temperature (OTP) protection signal.
(6) CV/CC status indicators.
(7) Output status indicators.
1.2.4

Input Control Signals

(1) Remote sense input for voltage drop compensation.
(2) Analog reference voltage (APG) input allowing voltage and current to be set by a voltage
source, current source, or resistance that adjusts for the panel setting.
(3) Remote inhibit control signal (TTL)
1.2.5
Measuring & Editing
(1) Measurements for voltage, current and power.
(2) 10 programs and 100 sequences to define voltage/current output waveforms.
(3) One run time voltage program that can be set for up to 99 hours.
(4) 10 programs and 100 sequences to define I-V curve output waveforms.
1.3

Specifications

Chroma 62000H Series High Power Density DC Power Supplies with Solar Array Simulation
offer 2KW (62020H), 5KW (62050H), 10KW (62100H) and 15KW (62150H) models based on
the output power and the power supply of each model. Table 1-1 lists the output specifications
of the 62000H Series 2KW, 5KW, 10KW and 15KW DC Power Supplies with Solar Array
Simulation. Warm up the instrument for at least 10 minutes before performing any test items.
The maximum DC Power Supply output voltage must be 5% less than full-scale. All
specifications are tested using Chroma's standard test procedures at 25 ± 5°C, on a remote
sense connection with a resistive load, unless specified otherwise.