Programmable DC Electronic Load 63600 Series Operation & Programming Manual
5.3.2.21 SYSTEM Subsystem
SYSTem:ERRor?
Type:
Description:
Setting Syntax:
Setting Parameters: None
Query Syntax:
Return Parameters: <ACCRD>,
Query Example:
SYSTem:REMote
Type:
Description:
Setting Syntax:
Setting Parameters: None
Setting Example:
SYSTem:LOCal
Type:
Description:
Setting Syntax:
Setting Parameters: None
Setting Example:
M
Type:
Description:
Setting Syntax:
Setting Parameters: <NR1>, 0: do not change, 1: CCL, 2: CCM, 3: CCH, 4: CRL, 5:
Example:
AC
Type:
Description:
5-92
All Channels
This command queries the error string of the command parser.
None
SYSTem:ERRor?.
0,"No Error",
1,Data Format Error",
2,Data Range Error",
3,Command Error",
4,Execution Error",
5,Too Many Errors"
SYST:ERR?
All Channels
This command can only be used under control of USB and Ethernet.
If SYST:REM is programmed, the 63600 will be set in the REMOTE
state, and the front panel of frame will be disabled except the
<LOCAL>key pressed.
SYSTem:REMote
SYST:REM
All Channels
This command can only be used under control of USB and Ethernet.
If SYST:LOC is programmed, the 63600 will be set in the LOCAL
state, and the front panel will work.
SYSTem:LOCal
SYST:LOC
All Channels
Set the load mode to the ten channels in one frame. The frame will
ignore the setting if the channel does not exist.
M<space>"n,n,n,n,n,n,n,n,n,n"
CRM, 6: CRH, 7: CVL, 8: CVM, 9: CVH, 10: CPL, 11: CPM, 12:
CPH, 13: CZL, 14: CZM, 15: CZH, 16: CCDL, 17: CCDM, 18: CCDH,
19: CCFSL, 20: CCFSM, 21: CCFSH, 22: TIML, 23: TIMM, 24:
TIMH, 25: SWDL, 26: SWDM, 27: SWDH, 28: OCPL, 29: OCPM, 30:
OCPH, 31: PROG, 34: MPPTL, 35: MPPTM, 36: MPPTH, 37:
UDWL, 38: UDWM, 39: UDWH
M "1,1,2,2,2,2,5,5,0,0"
M "2,2,2,2,2,2"
All Channels
Set the current level 1(L1) of CC mode to the ten channels in one
frame. The frame will ignore the setting if the channel does not exist.
Need help?
Do you have a question about the 63610-80-20 and is the answer not in the manual?