Programmable DC Electronic Load 63600 Series Operation & Programming Manual
:CONFigure
CONFigure:ALLRun
Type:
Description:
Setting Syntax:
Setting Parameters:<CRD | NR1>, OFF(0), ON(1)
Setting Example:
Query Syntax:
Return Parameters:<CRD>, OFF, ON
Query Example:
CONFigure:AUTO:ON
Type:
Description:
Setting Syntax:
Setting Parameters:<CRD | NR1>, OFF(0), ON(1)
Setting Example:
Query Syntax:
Return Parameters:<CRD>, OFF, ON [Unit = None]
Query Example:
CONFigure:EXTernal:WAVeform
Type:
Description:
Setting Syntax:
Setting Parameters:<CRD | NR1>, OFF(0), ON(1)
Setting Example:
Query Syntax:
Return Parameters:<CRD>, OFF, ON
Query Example:
5-40
:DIO
:IN1
:IN2
:OUT1
:OUT2
:VOLTage
Channel-Specific
Set the load module all run state.
CONFigure:ALLRun<space><CRD | NR1>
CONF:ALLR ON
CONF:ALLR 0
CONFigure:ALLRun?
CONF:ALLRun?
Channel-Specific
Set the load module to perform auto load on during power-on.
CONFigure:AUTO:ON<space><CRD | NR1>
CONF:AUTO:ON ON
CONF:AUTO:ON 0
CONFigure:AUTO:ON?
CONF:AUTO:ON?
Channel-Specific
Set the external waveform function on/off.
CONFigure:EXTernal:WAVeform<space><CRD | NR1>
CONF:EXT:WAV ON
CONF:EXT:WAV 0
CONFigure:EXTernal:WAVeform?
CONF:EXT:WAV?
SP
?
SP
?
SP
?
SP
?
SP
?
Set all run state to ON.
Set all run state to OFF.
[Unit = None]
Set auto load on state to ON.
Set auto load on state to OFF.
Set external waveform to ON.
Set external waveform to OFF.
[Unit = None]
<NR1>
<NR1>
<NR1>
<NR1>
<NR1>
<NR1>
<NR1>
<NR1>
<NR1>
<NR1>