Outlet # is 1-8 for SLP8 and 1-16 for SLP16 units.
The outletcontrol parameters control individual outlets.
slp outletstate [outlet <Outlet #>]
The outletstate parameter shows the state of all outlets or a single outlet.
slp envmon
Displays the environmental status (e.g., temperature and humidity) of the SLP power manager.
slp infeedstatus
Displays the infeed status and load of the SLP unit.
slp system
Provides system information for the SLP power manager.
sensorsoft lowtemp <Low Temperature in C.>
Sets the lowest temperature permitted for the port.
sensorsoft hightemp <High Temperature in C.>
Sets the hightest temperature permitted for the port.
sensorsoft lowhumidity <Low Humidity %>
Sets the lowest humidity pemitted for the port.
sensorsoft highhumidity <High Humidity %>
Sets the lowest humidity permitted for the port.
sensorsoft traps <enable|disable>
Enables or disables traps when specified conditions are met.
sensorsoft status
Displays the status of the port.
Description
Sends commands to (or control) a device connected to an SLB device port over the serial port.
Note:
Currently the only devices supported for this type of interaction are the SLP power
manager and Sensorsoft devices.

Device Port Commands

set deviceport port
Syntax
set deviceport port <Device Port # or List or Name> <one or more
parameters>
SLB™ Branch Office Manager User Guide
14: Command Reference
291