Boot Banks; Load Firmware Via Options - Lantronix 100-120 VAC SLB User Manual

Branch office manager
Table of Contents

Advertisement

Load Firmware via

Boot Banks

Note:
The first time boot for each bank may take up to 5 minutes. Subsequent boot
times will be approximately 2 minutes.
Bank 1
Bank 2
Next Boot Bank
Switch to Bank 2
Copy configuration
from Bank 1 to Bank 3
during firmware update
Copy contents of
Bank 1 to Bank 2
High Resolution Timers

Load Firmware Via Options

HTTPS
NFS Mounted Dir
USB Port
FTP/SFTP/TFTP
Server
Path
Login
Password /
Retype Password
SLB™ Branch Office Manager User Guide
From the drop-down list, select the method of loading the firmware. Options are
FTP, TFTP, HTTPS, NFS, USB, and SFTP (Secure FTP). TFTP is the default. If
you select HTTPS, the Upload File link becomes active. Select the link to open a
popup window that allows you to browse to a firmware update file to upload.
Displays the version of SLB firmware in bank 1.
Note:
The word "current" displays next to the bank from which the SLB branch
office manager booted.
Displays the version of SLB firmware in bank 2.
Displays the current setting for bank to boot from at next reboot.
If desired, select the alternate bank to boot from at next reboot.
If checked, will copy the configuration from the current bank to the bank being
updated. The two numbers are automatically generated so that the first
number is the current bank.
If checked, enables you to copy the current boot bank to the alternate boot
bank. This process takes a few minutes to complete.
Enables or disables timers with a high degree of accuracy. High resolution
timers are required for
Performance Monitoring (on page
SLC performance if they are enabled. Off by default. Changing this value
requires a reboot for the change to take effect.
Click the Upload File link to browse to the file to update the SLB firmware.
Select the NFS mounted directory from the drop-down menu.
Click to select USB port.
The IP address or host name of the server used for obtaining updates and saving
or restoring configurations. May have up to 64 alphanumeric characters; may
include hyphens and underscores.
The default path on the server for obtaining firmware update files and getting and
putting configuration save files.
The userid for accessing the FTP server. May be blank.
The FTP user password.
12: Maintenance
74), but may affect
229

Advertisement

Table of Contents
loading

This manual is also suitable for:

200-240 vac slb

Table of Contents