2. Enter the following:
Event Trigger
Action
Ethernet
Modem Connection
on
NMS/Host to forward
trap to
SNMP Community
SLB™ Branch Office Manager User Guide
Figure 12-12 Maintenance > Events
From the drop-down list, select the type of incident that triggers an event. Currently,
the options are:
Receive Trap
Temperature Over/Under Limit (for Sensorsoft devices)
Humidity Over/Under Limit (for Sensorsoft devices)
Device Port Data Drop
Current Over Threshold
Power Inlet Status Change
No Internal Modem Dial Tone
From the drop-down list, select the action taken because of the trigger. For
example, the action can be writing an entry into the syslog with details of the event
or sending the trap(s) to the Ethernet or modem connection.
For actions that require an Ethernet connection (for example, Forward All Traps to
Ethernet), select the Ethernet port to use.
For actions that require a modem connection (for example, Forward All Traps to a
Modem Connection, select which device port or USB port with a modem
connection to use.
For actions that forward a trap, enter the IP address of the computer to forward the
trap to. The computer does not have to be an SNMP NMS; it just has to be capable
of receiving SNMP traps.
Forwarded traps are sent with this SNMP community value
There is no default.