Data Settings; Gsm/Gprs Settings; Modem Settings - Lantronix 100-120 VAC SLB User Manual

Branch office manager
Table of Contents

Advertisement

3. Enter the following fields.

Data Settings

Note:
Check the modem's equipment settings and documentation for the proper
settings. The attached modem must have the same settings.
Baud
Data Bits
Parity
Stop Bits
Flow Control

GSM/GPRS Settings

Dial-out Mode
PIN
Retype PIN
PPP Compression
Auto-acquire DNS
Negotiated IP
GPRS Context
GSM Bearer Svc

Modem Settings

Note:
Depending on the State and Mode you select, different fields are available.
State
SLB™ Branch Office Manager User Guide
The speed with which the device port exchanges data with the attached serial
device.
From the drop-down list, select the baud rate. Most devices use 9600 for the
administration port, so the device port defaults to this value. Check the equipment
settings and documentation for the proper baud rate.
Number of data bits used to transmit a character. From the drop-down list, select
the number of data bits. The default is 8 data bits.
Parity checking is a rudimentary method of detecting simple, single-bit errors.
From the drop-down list, select the parity. The default is none.
The number of stop bit(s) used to indicate that a byte of data has been transmitted.
From the drop-down list, select the number of stop bits. The default is 1.
A method of preventing buffer overflow and loss of data. The available methods
include none, xon/xoff (software), and RTS/CTS (hardware). The default is none.
Select either GPRS or GSM (Global System for Mobile communication) as the
type of dial-out connection.
Enter PIN (personal identification number) for accessing the GSM/GPRS card.
Re-enter PIN (personal identification number) for accessing the GSM/GPRS card.
Select to enable negotiation of data compression over PPP links. Disabled by
default.
Select to enable the SLB branch office manager to acquire up to three DNS
servers by means of GPRS (General Packet Radio Service). Enabled by default.
IP address associated with the GPRS connection.
Command to specify the protocol data packet (PDP) context parameter values.
Command to select the bearer service, data rate, and connection element to use
when data call originate.
Indicates whether an external modem is attached to the device port. If enabling,
set the modem to dial-out, dial-in, dial-back, dial-on-demand, dial-in/host list, or
dial in & dial-on-demand. Disabled by default.
9: USB Port
175