12 Setting Machine Parameters

12.1 Setting the Parameters for the System Specifications

(1) On the Mainte screen, select [Mainte] and then [Psswd input]. Enter the machine parameter password in the setting
area and press the [INPUT] key.
(2) Go back to the Mainte screen.Then select [Param].
Set the parameters according to the system specifications.
"#1001 SYS_ON(System validation setup)"
"#1002 axisno(Number of axes)"
"#1003 iunit(Input setup unit)"
"#1004 ctrl_unit(Control unit)"
"#1005 plcunit(PLC unit)"
"#1006 mcmpunit(Machine error compensation unit)"
"#1037 cmdtyp(Command type)"
"#1039 spinno(Number of spindles)"
"#1155 DOOR_m"...Set to "100".
"#1156 DOOR_s"... Set to "100".
"#1511 DOORPm(Signal input device 1 for door interlock II: for each system)"
"#1512 DOORPs(Signal input device 2 for door interlock II: for each system)"
(3) After turning the power OFF and ON, select [Mainte] on the maintenance screen, switch the menu by the Menu
change button and then select [Format].
(4) When "Input the password" is displayed, enter the password for the machine parameter in the setting area and then
press [INPUT] key.
(5) When "Data protect" is displayed, select [I/F dia] on the Diagnosis screen, select [Modal output] and then enter
"Y70A/1".
(6) Select [Mainte] on the maintenance screen and then select [Format].
(7) When "Format NC memory? (Y/N)" is displayed, press "Y". "Format complete" will be displayed.
(8) Turn the power ON again and select [Mainte] --> [Psswd input] on the maintenance screen. Enter the password for
the machine parameter and then press [INPUT].
Select [Param] again on the Mainte screen. Set the following parameters.
"#1010 srvunit(Output unit(servo))"
"#1013 axname(Axis name)"
(Note)
When the arbitrary axis exchange control is valid, set the axis names in "#12071 adr_abs[1]" to
"#12078 adr_abs[8]".
"#1021 mcp_no(Drive unit I/F channel No. (servo)))"
Set the following parameters as needed.
"#1014 incax(Increment command axis name)"
(Note)
When the arbitrary axis exchange control is valid, set the increment command axis name in "#12079
adr_inc[1]" to "#12086 adr_inc[8]".
"#1015 cunit(Command unit)"
"#1017 rot(Rotational axis)"
"#1018 ccw(Motor CCW)"
"#1019 dia(Diameter specification axis)"
"#1020 sp_ax(Spindle interpolation)"
"#1022 axname2(2nd axis name)"
(9) Turn the power OFF and ON.
IB-1501452-C
172