C80 Series Connection and Setup Manual
14 Setting the Position Detection System

14.1.2 Basic Position Alignment Method II

(1)
Preparations
Set the parameters on the
[Abs.Posit.Param.] screen.
(2)
Turn the power OFF and ON.
(Only when #2049 has been reset.)
The following are the operations on [Absolute position setting screen].(Select [Mainte] -> [To Abs pos])
(3)
Select the axis set to type 4 on the
[Abs.Posit.Param.] screen.
Select the menu [Axis select], enter
the axis name (#1022 axname2
(display axis name)) in the input area
and then press [INPUT].
(4)
Select "HANDLE", "HANDL_AXIS", or
"JOG" for the machine operation
switch.
(5)
Confirm that the cursor is placed on
"Absolute posn set", input "1" in the
input area and press the [INPUT] key.
(6)
Move the cursor to "Zero-P" with
the [ ↑ ] and [ ↓ ] keys.
Enter the value in the input area of
"Zero-P" and press the [INPUT] key.
(* 1)
#2049 type (absolute position detection type) = 4
#2059 zerbas (zero return parameter) =0
The parameters other than #2049 type can also be set in [Absolute
position setting screen].
The input value is registered in the "Absolute posn set" area.
The input value is registered in the "Zero-P" area.
191
(marked point alignment method II)
(position where the axis was stopped)
IB-1501452-C