Mitsubishi Electric C80 Series Connection And Set Up Manual page 188

Hide thumbs Also See for C80 Series:
Table of Contents

Advertisement

C80 Series Connection and Setup Manual
11 CNC CPU Initial Setup
(5) Perform the device setting on CPU side.
[When connecting one unit of CNC CPU]
(Note)
When the [Execute init.] menu is pressed at NC1, the settings for (a) to (b) are performed
automatically.
The setting of [Setting example 1] is applied to (a).
(a) Make the device setting on the CPU1 side.
[Setting example 1]
CPU1 (PLC CPU side)... an example of one unit of CNC CPU, 2-part system and 8 control axes
[Setting example 2]
Setting example when using [Setup] - [T-reg] screen under the condition of setting example 1
(b) Make the device setting on the CPU2 side.
Press [Next CPU] at the bottom right. Confirm that [CPU2] is displayed in the top right.
CPU2 (CNC CPU side)... an example of one unit of CNC CPU, 2-part system and 8 control axes
157