1001
SYS_ON
Part system
(PR)
validation
setup
1002
axisno
Number of
(PR)
axes
1003
iunit
Input setup
(PR)
unit
1013 axname Axis name
1014 incax
Increment
command
axis name
1015
cunit
Command
(PR)
unit
1016
iout
Inch output
(PR)
5. Base Specifications Parameters
Details
Specify the presence of the PLC axes and the 1st to
7th part systems with 1 or 0.
Set No. of axes in each part system and the No. of PLC
axes.
Set so that the total of the NC axes and PLC axes is
less than the maximum number of controllable axes.
Specify the input setting value for each part system
and the PLC axis. The parameter units will follow this
specification.
Specify each axis' name address with an alphabetic
character.
Use the characters X‚ Y‚ Z‚ U‚ V‚ W‚ A‚ B or C.
Do not specify the same address in one part system.
The same address can be specified as the other part
system.
The PLC address does not need to be set. (The axis
name is displayed as 1 and 2.)
When specifying the program movement rate's
absolute or incremental method with an address‚
specify the incremental command axis name address
with an alphabetic character.
The address that can be used is the same as "#1013
axname".
Specify an address that is different from that #1013.
Setting is not required if absolute/incremental command
with addresses is not performed ("#1076 Abslnc" = 0).
Specify the minimum unit of the program movement
amount.
cunit
Movement amount for movement command 1
1 µm)
10: 0.001 mm (
mm ( 10 µm)
100: 0.01
mm (100 µm)
1000: 0.1
10000: 1.0
mm
If there is a decimal point in the movement command‚
the decimal point position will be handled as 1mm
regardless of this setting.
Specify whether the machine system (ball screw pitch‚
position detection unit) is an inch unit system or metric
unit system.
15
Get other manuals https://www.bkmanuals.com
Setting range (unit)
0: Not used
1: Used
0 to 14
B: 1 µm
C: 0.1 µm
Axis addresses
such as X, Y, Z, U,
V, W, A, B, and C
1 µm
10
10 µm
100
100 µm
1000
10000
1 mm
0: Metric unit
system
1: Inch unit system