15 Setting the Tool Entry Prohibited Range

15.2.5 Stored Stroke Limit IC

The boundary is set for each axis with the axis parameters "#2061 OT_1B-" and "#2062 OT_1B+". The inside of the set
boundary is the machine movement valid range.
This is valid when the axis parameter "#2063 OT_1Btype (Soft limit IB type)" is set to "2". Cannot be used with soft limit
IB.
IB-1501452-C
2
: Moveable range
: Prohibited range
Point 3: "#2062 OT_1B+ (Soft limit IB+)" and
Point 4: "#2061 OT_1B- (Soft limit IB-)" are set with the coordinate values in the basic machine
coordinate system.
Points 1 and 2 are the prohibited range set with stored stroke limit I.