Dual Signal Module - Mitsubishi Electric C80 Series Connection And Set Up Manual

Hide thumbs Also See for C80 Series:
Table of Contents

Advertisement

C80 Series Connection and Setup Manual
4 General Specifications

4.6 Dual Signal Module

Use the dual signal module within the following specifications.
Items
Number of input points
Input insulation method
Rated input voltage
Rated input current
Input derating
ON voltage/ON current
OFF voltage/OFF current
Input resistance
Input response time
Input common method
Input type
Number of output points
Output insulation method
Rated load voltage
Maximum load current
Utilization category
Maximum rush current
OFF-time leakage current
ON-time maximum voltage drop
Output response time
Output common method
Output
Surge suppressor
Fuse
Voltage
External power supply
Electric current 40mA
Protection
Withstand voltage
Insulation resistance
Noise withstand level
Protection degree
Number of I/O occupational points
Operation display
External connection method
Applicable size of wire
Connector for external wiring
Terminal block changeover unit
5VDC internal power dissipation
Mass
32 points x 2 systems (32 points for PLC CPU control + 32 points for CNC CPU control, 20
points x 2 systems for safety input, 12 points x 2 systems for feedback input for output)
Photocoupler insulation
24VDC (+20/-15%, ripple ratio within 5%)
Approximate 4mA
Refer to the derating figure
19V or more/3mA or more
4V or less / 1.7mA or less
Approximate 5.6kΩ
1ms
32 points/common
(Common terminal 1A01, 1A02, 2A01, 2A02)
(Each part-system has a different common.)
Type 1, Current sinking
12 points x 2 systems
Photocoupler insulation
24VDC (+20/-15%)
(0.1A x 8 points, 0.2A x 4 points) x 2 systems
Common current: 1.6A or less for each connector
DC12/DC13
0.7A,10ms or less (1.4A, 10ms or less for 0.2A output pin)
0.1mA or less
0.1VDC(TYP.)0.1A, 0.2VDC(MAX.)0.1A
1ms or less (at rated load and resistance load)
12 points/common
(Common terminal 1B01, 1B02, 2B01, 2B02)
(Each part-system has a different common.)
Current sourcing
Zener diode
Not provided
24VDC (+20/-15%, ripple ratio within 5%)
Provided (thermal protection and short circuit protection)
Thermal protection works for each 2 points.
Short circuit protection works for each 1 point. (1 to 3A/point)
560VAC rms/3cycles (at 2000m elevation)
10MΩ or more (measured with an insulation resistance tester)
Simulator noise 500Vp-p, Noise width 1μs
measured with a noise simulator with noise frequency 25 to 60Hz
First transient noise IEC61000-4-4: 1kV
IP2X
32 points (with I/O assignments as 32 points I/O mixed unit)
ON display (LED) and 32 input points display for PLC CPU control
40-pin connector
2
0.3mm
(for A6CON1 and A6CON4)
A6CON1, A6CON2, A6CON3, A6CON4 (sold separately)
FA-LTB40P (Cable FA-CBL □□ FMV-M)
200mA (TYP. when all points are ON)
0.14kg
47
Specifications
R173SXY
IB-1501452-C

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents