4 General Specifications
(8) MPG
Connector for 5V manual pulse generator
1
6
70553-0005
(MOLEX)
Input pulse signal type: 90°phase difference between HA1 and HB1
Max. input pulse frequency: 5kHz
Number of pulses per rotation: 100pulse/rev
Input signal voltage: H level 3.5V to 5.25V, L level 0V to 0.5V
For pulse generators
Power voltage for pulse generators : 5VDC±10%
Max. output current: 100mA
HA1(HB1)
HB1(HA1)
a.b.c.d.e: HA1 or HB1 rising edge (falling edge) phase difference = T/4 ± T/10
T: Ha1 or HB1 phase cycle (Min. 10μs)
(9) RIO
Connector for Dual signal module
1
3
70553-0002
(MOLEX)
1
OUT
5VDC
2
IN
HA1
3
IN
HB1
4
OUT
SG(0V)
5
-
6
FG
a
b
c
d
e
T
1
IN/OUT
RXTXH
2
IN/OUT
RXTXL
3
SG(V)
1
+5VDC
470Ω
2
HA1
470Ω
HB1
3
4
SG(0V)
6
FG
45
+5VDC
220Ω
4700pF
0V
220Ω
4700pF
0V
0V
FG