Connecting The Skip Signal (Sensor) - Mitsubishi Electric C80 Series Connection And Set Up Manual

Hide thumbs Also See for C80 Series:
Table of Contents

Advertisement

C80 Series Connection and Setup Manual
6 Wiring and Connecting

6.8 Connecting the Skip Signal (Sensor)

Connect the skip signals to the connector EXT I/F on CNC CPU module, or the connector SKIP on signal splitter.
H300 cable is used as composite cable with manual pulse generators. Use a terminal block for the relay connection.
Skip signals are used for processing the high-speed signals. Shielding is necessary for the cable that connects the
terminal block and the sensor.
H310 cable is applied when the signal splitter (FCU7-HN387) is used.
[Connecting directly to CNC CPU module]
EXT I/F
(Note 1) H300 cable is a composite cable with manual pulse generator(s).
(Note 2) Refer to "(10) EXT I/F" in "4.5 CNC CPU Module" for the specification details.
[Connecting via signal splitter]
EXT I/F
R16NCCPU
(Note 1) Be sure to connect the terminal block FG of the signal splitter to the ground (FG).
(Note 2) Refer to "(4) SKIP" in "4.7 Signal Splitter" for the specification details.
<Related items>
Cable drawing: "Cable: H300 Cable, H310 Cable"
H300
Terminal block
H010
NC I/F
FCU7-HN387
83
To be prepared
by user
Sensor
H310
Terminal block
SKIP
FG
To be prepared
by user
Sensor
IB-1501452-C