15 Setting the Tool Entry Prohibited Range

15.2.3 Stored Stroke Limit II

The boundary is set with the axis parameters "#8204 OT-CHECK-N" and "#8205 OT-CHECK-P" or with program
commands. Either the inside or the outside of the set boundary is the prohibited range. Whether the inside or outside of
the range is prohibited is determined by "#8210 OT-INSIDE". When the inside is selected, this function is called stored
stroke limit IIB.
When using program commands, entry of the tool into the prohibited range is prohibited with G22, and entry into the
prohibited range is enabled with G23. The stored stroke limit II can be invalidated for each axis with setting "#8202 OT-
CHECK OFF" to "1".
Prohibited range
X: Outside Z: Outside
X
(1) Stored stroke limit II (When prohibited range is on outside)
When used with the stored stroke limit I function, the narrow range designated by the two types becomes the
movement valid range.
X: Inside Z: Outside
X
Z
: Moveable range
: Prohibited range
(C)
4
2
: Moveable range
: Prohibited range
(A): Set value for (-) side
(B): Set value for (+) side
(C): Prohibited range by stored stroke limit II
Point 3: "#8205 OT-CHECK-P" and
Point 4: "#8204 OT-CHECK-N" are set with the coordinate values in the basic machine
coordinate system.
Points 1 and 2 are the prohibited range set with stored stroke limit I.
X: Inside Z: Inside
Z
3
(A)
(B)
215
X
Z
1
IB-1501452-C