7 Cable

7.3.2 CNP2E-1 Cable

Max. cable length: 30m
Application: Motor side PLG cable
Spindle side accuracy detector
TS5690 cable
Spindle drive unit side connector
Receptacle: 36210-0100PL
Shell kit: 36310-3200-008
Connector set: 54599-1019
Spindle drive unit side connector
Receptacle: 36210-0100PL
Shell kit: 36310-3200-008
Connector set: 54599-1019
IB-1501452-C
(3M)
 
(MOLEX)
1
P5(+5V)
2
LG
5
MT1
6
MT2
7
SD
8
SD*
3
RQ
4
RQ*
Case
PE
grounding
(Note) For the pin "7" or "8", use the contact "170364-1".
For the other pins, use the contact "170363-1".
<Cable connection diagram (for 15m or less)>
(3M)
 
(MOLEX)
1
P5(+5V)
2
LG
5
MT1
6
MT2
7
SD
8
SD*
3
RQ
4
RQ*
Case
PE
grounding
(Note) For the pin "7" or "8", use the contact "170364-1".
For the other pins, use the contact "170363-1".
<Cable connection diagram (for 15m to 30m)>
Spindle motor side connector
(Tyco Electronics)
Connector: 172169-1
Contact: 170363-1(AWG26-22)
170364-1(AWG22-18)
(Note)
7
P5(+5V)
2
0.5mm
8
LG
2
MT1
2
0.2mm
1
MT2
5
SD
2
0.2mm
6
SD*
3
RQ
2
0.2mm
4
RQ*
9
SHD
Spindle motor side connector
(Tyco Electronics)
Connector: 172169-1
Contact: 170363-1(AWG26-22)
170364-1(AWG22-18)
2
0.5mm
(Note)
7
P5(+5V)
2
0.5mm
8
LG
2
MT1
2
0.2mm
1
MT2
5
SD
2
0.2mm
6
SD*
3
RQ
2
0.2mm
4
RQ*
9
SHD