4 General Specifications
(5) MPG
5V/12V Connector for manual pulse generator
1
9
15
8
D-SUB 15pin
Input pulse signal type
Input signal voltage
Max. input pulse
frequency
Pulse generators power
supply voltage
Current consumption
Number of pulses per
rotation
HA1 (HB1)
HB1 (HA1)
a.b.c.d.e: HA1 or HB1 rising edge (falling edge) phase difference = T/4 ± T/10
T: HA1 or HB1 cycle (Min. 10μs)
Signal
input
(Note)
12V
Power
5V
output
Power
output
(Note) 12V power is separately required to connect 12V manual pulse generator.
(Refer to "6.9 Connecting the Manual Pulse Generator".)
(6) TERMINAL
(Not used)
1
IN
HA1
2
IN
HB1
3
IN
HA2
4
IN
HB2
5
IN
HA3
6
IN
HB3
7
OUT
+5VDC
8
OUT
+5VDC
5V manual pulse generator (UFO-01-2Z9)
input conditions
HA1 and HB1 phases (with phase difference 90°) (Refer to the waveform below.)
100 pulse/rev
a
b
c
d
e
T
Signal Splitter
+5V
MPG
HA1
1
HA2
3
HA3
5
0.1μF
+5V
HB1
2
4
HB2
6
HB3
0.1μF
12V
+12V
10
+12V
12
+12V
14
+5V
7
+5V
8
9
0V
11
0V
13
0V
0V
9
OUT
SG(0V)
10
OUT
+12VDC
11
OUT
SG(0V)
12
OUT
+12VDC
13
OUT
SG(0V)
14
OUT
+12VDC
15
---
12V manual pulse generator (HD60C)
H level 3.5V to 5.25V
L level 0V to 0.5V
5kHz
5VDC±10%
100mA or less
CNC CPU
0V
Control
unit
0V
53
input conditions
12VDC±10%
25 pulse/rev
IB-1501452-C