Environmental Specifiactions; Electrical Specifications - BENSHAW RSi GX Series Hardware Manual

Sensorless vector variable frequency drive
Table of Contents

Advertisement

2 - TECHNICAL SPECIFICATIONS
Environmental Specifications
2.2

Environmental Specifiactions

Protection degree
Ambient temperature
Storage temperature
Humidity
Altitude
Maximum vibration
Cooling
Atmospheric pressure
Location

Electrical Specifications

2.3
Electrical Specifications
Voltage input
Line frequency
DC bus voltage for:
Overvoltage trip
Dynamic Brake
activation
Nominal undervoltage
(UV) trip
Control system
Output voltage
Overload capacity
Rated output frequency 50/60Hz ±5%
Frequency range
Frequency stability
Frequency setting
Agency listings
12
Table 1
IP 20, NEMA TYPE 1 (Option)
-10°C to +50°C (non-freezing)
-20°C to +65°C (-4°F to 149°F)
0% to 95% RH (non-condensing)
Max. 1,000m (3300ft) without derating
2
5.9 m/s
(19.2 ft/s
Natural convection (1HP models)
Fan cooling (2HP and larger models)
70 to 106 kPa
Protected from corrosive gas, combustible gas, oil
mist or dust
Table 2
200VAC Models
3f 200 - 230VAC -10%, -15% 3f 380 - 480VAC +10%, -15%
50 / 60Hz ±5%
407VDC
391VDC
202VDC
Voltage Vector pulse width modulation (PWM)
Carrier frequency = 4, 6, 8, 12, and 16kHz
0 to 100% of line voltage, Three-phase
150% of rated rms for 60 seconds
0 to 1000Hz
±0.02Hz from 0 to 300Hz (digital)
±0.01Hz from 300 to 1000Hz (digital)
0.1% (analog) over 24 hours ±10°C change
Digital: keypad (0 to 10VDC, -10 to 10VDC, 0 to 20mA)
UL and cUL Listed, CE Mark
2
) [0.6G] or less
400VAC Models
805VDC
780VDC
510VDC

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents